18mm Inductive Proximity Sensor EN 60079/IEC 60079 (Dust zone21/Gas zone1)
SYNATEL design & manufacture a range of 18mm inductive proximity sensors, available as 4 wire DC or 2 wire FET multivoltage units. Non flush. Ideal for target detection on rotating/reciprocating machinery.
ATEX EN60079 & IECEx IEC 60079 gas & dust hazard area use approvals.
ID/E1MOAI – 4 wire npn/pnp protected output 30V dc 100mA max. Output state selectable by supply connections reversal. 10-30V dc supply.
ID1MZAI – 2 Wire FET output. Normally De-energised. 24-240V ac/dc 50mA max.
IE1MZAI – 2 wire FET output. Normally Energised. 24-240V ac/dc 50mA max.
18mm Inductive Proximity Sensor
ATEX EN 60079/IECEx 60079
(Dust zone21/Gas zone1)
To purchase this item please contact the 4B Group
Visit 4B Group
Visit 4B Group
Downloads
- 18mm 4 wire Proximity Sensors Manual
- 18mm 2 wire Proximity Sensor Manual
- Baseefa14atex0115x-18mmgeneric-mk3
- 18mm IECEx Certificate IEC 60079
- Latest Approvals Specification
You may also like...
Data/Specifications
4 Wire DC ID/E1MOAI | 2 Wire Multivoltage ID1MZAI / IE1MZAI | |
---|---|---|
Supply | 10-30V dc | 24-240V ac/dc |
Fusing | 1500A Capable, 500mA max. 1 per sensor MUST be used | 1500A Capable, 500mA max. 1 per sensor MUST be used |
Output | Fully Opto-isolated transistor. Reverse & over-voltage protected. npn/pnp configurable | 2 wire FET |
Output State | User selectable | ID1MZAI - De-energised with NO target IE1MZAI - Energised with NO target |
Output Rating | 30V DC 100mA max | 50mA max |
Operating Range | 8mm on ferrous target | 8mm on ferrous target |
Hysterisis | 15% of operating Range | 15% of operating range |
Ambient Temperature | -15°C to +50°C | -15°C to +50°C |
IP Rating | IP66 | IP66 |
Enclosure | Nylon 66/6 | Nylon 66/6 |
Connections | 4 core, PVC, unscreened | 2 core, PVC, unscreened |
Weight | 260g | 260g |
Approval | II 2G Ex mb IIC T5 Gb II 2D Ex mb IIIC T100° Db I M2 Ex mb I Mb Tamb = -15°C to +50°C IP66 (Dust zone 21/Gas zone 1/Mining) | II 2G Ex mb IIC T5 Gb II 2D Ex mb IIIC T100° Db I M2 Ex mb I Mb Tamb = -15°C to +50°C IP66 (Dust zone 21/Gas zone 1/Mining) |
Dimensions
Connections
ID/E1MOAI – 4 Wire
ID1MZAI / IE1MZAI – 2 Wire