+44 (0)1543 277003

ROTASLIP PU1TZAI/PU1TRHAI Underspeed Monitor
ATEX EN 60079/IECEx 60079

atex-iecex-appROTASLIP Underspeed Monitor EN 60079/IEC 60079 (Dust zone20/Gas zone0)
The Rotaslip PU1TZAI & PU1TRHAI underspeed monitors from SYNATEL are designed to detect a stud or bolt on a shaft and indicates a fault condition (open circuit) if the input speed reduces by 20% or more below set running speed. Available as a 2 wire, 24-240V ac/dc supply, FET output – PU1TZAI or a 5 wire, 15-240V dc/24-240V ac supply, relay output – PU1TRHAI underspeed sensor. Ideal for belt driven applications.
ATEX EN 60079 & IECEx  IEC 60079 dust & gas hazard area use approved. (Rotaslip PU1TZAI & PU1TRHAI underspeed Monitor).

Data/Specifications

PU1TRHAIPU1TZAI
Supply15-25V dc / 24-240V ac24-240V ac/dc
Fusing1500A capable, 500mA max.
1 per sensor MUST be used
1500A capable, 500mA max.
1 per sensor MUST be used
OutputSPCO 3A 240V max. Non-inductive 2 wire FET, max current 100mA
Output StateOutput energised (ON) at set running speed,
de-energises if rotation falls 20% or more below set speed
Output energised (ON) at set running speed,
de-energises if rotation falls 20% or more below set speed
Operating Range8mm of ferrous target8mm of ferrous target
Hysterisis15% of operating range15% of operating range
Operating Speed10-3600 ppm (pulses per minute)10-3600 ppm (pulses per minute)
CalibrationStart-up delay & set running speed
User programmable using magnet (supplied),
applied to a target area on body of sensor.
Automatically calibrates for 20% below normal running speed
Start-up delay & set running speed
User programmable using magnet (supplied),
applied to a target area on body of sensor.
Automatically calibrates for 20% below normal running speed
Start-up DelayProgrammable start-up delay.
Output energises for time period irrespective of incoming pulse signal,
allows machinery to achieve running speed.
Max 30 second delay
Programmable start-up delay.
Output energises for time period irrespective of incoming pulse signal,
allows machinery to achieve running speed.
Max 30 second delay
Ambient Temperature-15°C to +50°C-15°C to +50°C
IP RatingIP66IP66
EnclosureNylon 66/6Nylon 66/6
Connections5 core, PVC, unscreened2 core, PVC, unscreened
Weight300g300g
ApprovalexII 1G Ex ma IIC T4 Ga
exII 1D Ex ma IIIC T110°C Da
Tamb = -15°C to +50°C IP66
(Dust zone 21/Gas zone 1) (2GD)
exII 1G Ex ma IIC T4 Ga
exII 1D Ex ma IIIC T 200110°C Da
Tamb = -15°C to +50°C IP66
(Dust zone 20/Gas zone 0) (1GD)

Dimensions

ai-30mm-dim-ind1

Connections

PU1TZAI
2Wire FET connections

PU1TRHAI
PU1TRHAI Connections

Enquire about this product

Part of the DonElec Group